Motive Tech Bulletin-4 Summit Series II

24VDC Single Voltage Configuration for Summit Series II 30400 Chargers

Downloadable version

Overview:

Multi-volt Summit II Battery Chargers can be converted to single voltage chargers if end users do not require multi-volt operation. This document lists the programming step required for single-voltage operation in 24 VDC applications.

Step 1

Enable the Bluetooth® wireless option on your smart device and launch the ChargerConnect™ App. Select your charger from the drop down list (default name will be the serial number of your charger) and select it to establish communication with your charger.

Charger connect cordset installation and system profile configuration.

Step 2

Allow the Dashboard to populate with real time data from your charger, observe the battery profile number listed on the display, the default profile number will be 22001. The battery profile must be changed to 22251 for 36 VDC single voltage operation.

A black cell phone with charger connection dashboard.

Step 3

Press the 3 lines in the upper left hand corner to view the drop down menu and select “Battery Profile”.

A black cell phone with a screen showing charger connections.

Step 4

Allow the Dashboard to populate with real time data from your charger and press the “Cloud Profiles” selection on the bottom of the display.

A black cell phone with a screen showing chargers.

Step 5

Find Battery Profile 22301 and press the green arrow key to the right to upload the profile to your device.

A black cell phone with a screen with a completion notification.

Step 6

Press the “Device Profiles” selection from the bottom of the display, then touch the arrow key next to profile 22051 to upload it to your charger.

A black cell phone with a screen for voltage configuration.

Step 7

The APP will the request additional information for the system profile setting, if your vehicle is a EZGO RXV Cart with a triangle DC Plug select “yes” if not select “no”.

A black cell phone with a screen displaying a message about a connected device.

Step 8

The APP will then ask for storage slot number for the profile to be transferred to your charger, enter “11”.

A black cell phone with a keyboard and a red button.

Step 9

The APP will then reboot the charger to assign the new battery profile. Once this action is complete, touch the serial number of the charger to re-establish communication.

A black cell phone with a blue button that says "Charger Connect".

Step 10

Once the charger is online, verify the proper battery profile is installed.

A black cell phone with a screen displaying a charging status.

Step 11

Press the three lines in the upper left hand corner to view this drop down menu, this time go to “System profile”.

A cell phone with a screen displaying a menu of options.

Step 12

Find the 36V or 48V Auto Profile and press the down arrow next to the “Scalable “ selection and view the drop down menu.

A cell phone screen with a Charger Connect app.

Step 13

Select “Off” from the menu and press OK.                                                      

A cell phone with a screen showing a menu for charging systems.

Step 14

A “Disable Scalable Profile” warning will appear to acknowledge the change request, select OK to proceed.

A cell phone with a red screen that says Charger Connect.

Step 15

Press the “Save” button to register the change.                                                              

A cell phone screen displaying a Charger Connect app.

Step 16

The charger will once again reboot to register the change. The charger will now operate in 24V Mode only.

A black cell phone with a blue button that says "Charger Connect".

Step 17

To view operation of the charger, Log back in, the charger should no longer identify a detected battery pack voltage.